category:energy / date:2022-08-18 12:08:32 / browse:157 / comment:4

Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment,Quinn Installation of fresh-keeping cold storage for vegetables and fruits, and do a good job in rain proof, moisture-proof, anti-collision,After the installation of the controlled atmosphere storage, the temperature is too low, perhaps because the unit is too large, which leads to the rapid decline of the air temperature in the controlled atmosphere storage. However, it can be found that the temperature of the goods is still at a high level, or perhaps because the thermal insulation effect of the controlled atmosphere storage is relatively poor after the installation of the controlled atmosphere storage, then the heat dissipation will be accelerated, we must pay attention to its thickness. Only the modified atmosphere storage board with the required thickness can have a certain thermal insulation effect.The refrigeration equipment in the fresh-keeping environment of the quick-frozen warehouse mostly adopts the single-stage compression refrigeration system, with freon as the refrigerant. The evaporation mode in the warehouse is the cooling fan, the refrigeration mode of the warehouse machine can be considered. If there are a large number of warehouses, the mode of multiple heads in parallel can be considered.Liperi,The quick-frozen warehouse is easy to load and unload. All the plates and walls of the quick-frozen warehouse are produced by molds. You can choose tens of millions of products. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage and transaction safety are guaranteed. Through internal concave convex groove connection, loading,Quinn Professional cold storage installation, unloading and handling are convenient. The installation period is short. Small and medium-sized cold storage can be delivered in - days The library body can be combined, separated or increased or decreased according to the needs of users.During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Wall and floor fixtures shall start at corners. According to the plate layout drawing transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, tighten the angle iron, and tighten it horizontally,Quinn Construction and installation cost of cold storage, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.


Quinn Price of medical cold storageCharacteristics of pneumatic conveying system



Cold storage design step: the selection of cold storage refrigeration system the selection of cold storage refrigeration system is mainly the use of cold storage refrigeration compressor and air conditioning evaporator. Generally, small and medium-sized refrigerators are dominated by fully enclosed refrigeration compressors. Due to the small output power of the fully enclosed refrigeration compressor, the price is relatively cost-effective; Small and medium-sized refrigerators are generally dominated by semi closed refrigeration compressors; Semi closed refrigeration compressor is adopted for large and medium-sized refrigerated warehouses. When adopting, ammonia refrigeration unit can also be considered. Because the output power of ammonia refrigeration unit is large and can be used for machine use, but the installation and management of refrigerated warehouses are cumbersome. When using the air-conditioning evaporator, the high-temperature cold storage uses the industrial cold fan as the air-conditioning evaporator. Its characteristic is that the temperature reduction speed is faster, but it is easy to lead to the water consumption of the cold collection; Medium and ultra-low temperature refrigerators are dominated by seamless evaporation pipe slots, which is characterized by very good temperature control effect and moderate cold storage.The area of wires in the conduit shall not exceed %.Other aspects: in the design process of food cold storage, it is also necessary to consider the cooperation between the cold storage and on-site fire fighting, ventilation, water and electricity systems. It should meet the requirements of safety, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following points should be paid attention to during redesign and installation.Inspection standard,The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is and unqualified products are not allowed to leave the factory.


Quinn Price of medical cold storageCharacteristics of pneumatic conveying system



The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.Bidding,If there is more air or refrigerant oil in the evaporator, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced the heat transfer efficiency will be significantly reduced, the cold storage needs to use phase electricity.The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed and the decline rate of warehouse temperature will be slowed down.Does the cable wire meet the parameters? In general, the wall panel joints shall be evenly sealed and decorated with silicone sealant.Quinn ,The lights in the warehouse are not on. Please check whether the switch fails and whether the bulb is damaged. Cut off the power supply when installing the lampshade, and pay attention to the waterproof of the lamp.The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

Comment area

share 4 Comments

user 35HP162657470 / 2022-08-18 12:30:53 / reply
The boss is so kind, he really knows his job well. Under your guidance, I will soon become an expert! The seller's service is really attentive. Bring colleagues together in the future. Very good Quinn Price of medical cold storage. Thank you.
user 570HP155642700 / 2022-08-18 12:44:16 / reply
The seller is really good, Quinn Price of medical cold storage is the same as the introduction, honest seller
user 409HP184720764 / 2022-08-18 13:00:31 / reply
I really like it, I am very supportive, the quality is very good, exactly the same as described in Quinn Price of medical cold storage, I am very satisfied, I really like it, completely exceed expectations, the delivery speed is very fast, the packaging is very careful and strict, and the logistics company services The attitude is very good, the delivery speed is very fast, and I am very satisfied with a shopping.
user 256HP158312377 / 2022-08-18 14:07:20 / reply
I'm quite satisfied, and the quality and workmanship are even worse. Look back and introduce to friends